Cumulative CAMAG Bibliography Service CCBS

Our CCBS database includes more than 11,000 abstracts of publications. Perform your own detailed search of TLC/HPTLC literature and find relevant information.

The Cumulative CAMAG Bibliography Service CCBS contains all abstracts of CBS issues beginning with CBS 51. The database is updated after the publication of every other CBS edition. Currently the Cumulative CAMAG Bibliography Service includes more than 11'000 abstracts of publications between 1983 and today. With the online version you can perform your own detailed TLC/HPTLC literature search:

  • Full text search: Enter a keyword, e.g. an author's name, a substance, a technique, a reagent or a term and see all related publications
  • Browse and search by CBS classification: Select one of the 38 CBS classification categories where you want to search by a keyword
  • Keyword register: select an initial character and browse associated keywords
  • Search by CBS edition: Select a CBS edition and find all related publications

Registered users can create a tailor made PDF of selected articles throughout CCBS search – simply use the cart icon on the right hand of each abstract to create your individual selection of abstracts. You can export your saved items to PDF by clicking the download icon.

Page
      111 067
      Development of HPTLC method for the estimation of antidepressant drugs melitracen and flupentixol in their combined dosage form
      U. CHHALOTIYA*, K. BHATT, D. SHAH, S. NAGDA, J. PATEL (*Indukaka Ipcowala College of Pharmacy, Beyond GIDC, P.B. No. 53, Vitthal Udyognagar- 388 121, Gujarat, India, usmangani84@gmail.com)

      J. Liq. Chromatogr. Relat. Technol. 36, 1231-1242 (2013). HPTLC of melitracen (1) and flupentixol (2) in combined dosage form on silica gel with methanol - toluene 4:1+1 drop ammonia. Quantitative determination by absorbance measurement at 270 nm. The hRf values of (1) and (2) were 79 and 88, respectively. Linearity was in the range of 1000-8000 ng/zone for (1) and 50-400 ng/zone for (2). LOD and LOQ were 225 and 683 ng/zone for (1) and 4.7 and 14.1 ng/zone for (2). Intermediate precision was below 3.6 %. Recovery (by standard addition) for (1) and (2) was in the range of 98.6-102.1 % and 97.8-101.8 %, respectively.

      Classification: 32a
      112 097
      Development and validation of an HPTLC–densitometric method for simultaneous analysis of lamivudine, tenofovir disoproxil fumarate, and efavirenz (LTE) in tablets
      B. NYAMWERU, E. KAALE*, V. MUGOYELA, M. CHAMBUSO (*Medicinal Chemistry and Allied Sciences and Pharm R&D Laboratory, School of Pharmacy, Muhimbili University of Health, Tanzania, wariwari@gmail.com)

      J. Planar Chromatogr. 26, 226-231 (2013). HPTLC of lamivudine (1), tenofovir disoproxil fumarate (2), and efavirenz (3) in tablets on silica gel with toluene - methanol 27:6. Quantitative determination by absorbance measurement at 254 nm. The hRf values for compounds (1) to (3) were 12, 16 and 53, respectively. Linearity was in the range of 375-900 ng/zone for (1) and (2) and 750-1800 ng/zone for (3). LOD and LOQ for (3) were 1 and 3 ng/zone. Recovery was in the range of 98.3-102.9 % for (1) to (3). Intermediate/interday/intra-day precision was below 2 % (n=6).

      Classification: 32a
      114 068
      Identification, isolation, and characterization of unknown degradation products of cefprozil monohydrate by high-performance thin-layer chromatography
      V. GAWANDE*, K. BOTHARA (*STES’s Sinhgad Institute of Pharmacy, Narhe Road,
      Narhe, Pune 411-041, India, gawandevandana848@gmail.com)

      J. Planar Chromatogr. 27, 372-376 (2014). For quality control, HPTLC of cefprozil monohydrate on silica gel with ethyl acetate – acetone – methanol – water – glacial acetic acid 15:5:5:3:1. Quantitative determination by absorbance measurement at 280 nm. The hRF value of cefprozil monohydrate was 20. Linearity was between 200 and 5000 ng/zone. The intermediate precision was below 1.5 % (n=3). The LOD and LOQ were 52 and 75 ng/zone, respectively. Recoveries were in the range of 98.7-101.2 %.

      Classification: 32a
      117 091
      A validated quantification of methadone in liquids using thin-layer chromatography and a flatbed scanner
      B. SPANGENBERG*, M. WEYANDT-SPANGENBERG (*University of Applied Sciences Offenburg, Institute of Process Engineering, Badstrasse 24, 77652 Offenburg, Germany, Spangenberg@HS-Offenburg.de)

      J. Planar Chromatogr. 29, 59-65 (2016). HPTLC of methadone in syrup on silica gel (1) or RP-18 (2) with methanol – 25 % ammonia 10:1. Detection by spraying with 1 mL of Dragendorff reagent. Quantitative determination using a flatbed scanner with a resolution of 16 bits. The hRF of methadone was 44 on (1) and 23 on (2). Linearity was in the range from 60 to 1260 ng/zone. The LOD and LOQ were 100 and 200 ng/zone, respectively. A total relative uncertainty of 6.5 % was achieved.

      Classification: 17a, 32a
      119 029
      Application of thin-layer chromatography and gas chromatography–mass spectrometry for evaluation of the chemical stability of hexyl nicotinate
      W. PARYS*, A. PYKA (*Department of Analytical Chemistry, School of Pharmacy with the Division of Laboratory Medicine in Sosnowiec, Medical University of Silesia in Katowice, Poland, wparys@sum.edu.pl)

      J. Planar Chromatogr. 30, 164-169 (2017). HPTLC of hexyl nicotinate on silica gel with acetone ‒ n-hexane 3:7. Chemical stability analysis was performed in aqua–ethanolic solutions stored in ordinary and quartz flasks heated at 40 °C and exposed to UV radiation at 254 nm. The main products of chemical changes of hexyl nicotinate are the substances with hRf 37 and 68. Preliminary identification of the decomposition products was achieved by GC–MS analysis.

      Classification: 4d, 32a
      121 067
      Stability-indicating high-performance thin-layer chromatographic determination of ondansetron in pure form and pharmaceutical formulations
      R. SARAYA*, R. SALAM, G. HADAD (*Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Port Said University, Port Said, Egypt, dr_saraya@yahoo.com)

      J. Planar Chromatogr. 31, 122-128 (2018). HPTLC of ondansetron with chloroform ‒ methanol ‒ ethyl acetate 7:2:1. Quantitative determination by absorbance measurement at 302 nm. The hRf value for ondansetron was 67. Linearity was in the range of 25-500 ng/zone. The intermediate precision was below 1 % (n=3). The LOD and LOQ were 5 and 15 ng/zone, respectively. Average recovery was 100.3 %. The method allowed the separation of the drug from its different degradation products.

      Classification: 23e, 32a
      122 085
      Stability-indicating high-performance thin-layer chromatographic method for the estimation of antipsychotic drug combination clozapine and aripiprazole
      V. PATEL, D. SHAH*, H. GOHIL, U. CHHALOTIYA (*Babaria Institute of Pharmacy, BITS EduCampus, Vadodara 391240, Gujarat, India, dimalgroup@yahoo.com)

      J. Planar Chromatogr. 31, 397-403 (2018). HPTLC of clozapine (1) and aripiprazole (2) on silica gel with toluene ‒ methanol ‒ ethyl acetate ‒ ammonia 65:25:10:1. Quantitative determination by absorbance measurement at 218 nm. The hRF values for (1) and (2) were 43 and 60, respectively. Linearity was between 200 and 1600 ng/zone for (1) and 100 and 800 ng/zone for (2). LOD and LOQ were 34 and 103 ng/zone for (1) and 20 and 60 ng/zone for (2), respectively. The intermediate precision was <2 % (n=3). Recovery ranged between 98.2-99.9 % for (1) and 98.7-99.5 % for (2).

      Classification: 32a
      56 090
      Chromatography of bis-quaternary amino-steroids
      M. GAZDAG, G. SZEPESI, K. VARSANYI-RIEDL, Z. VEGH, Z. PAP-SZIKLAY

      1. Separation on silica by thin-layer and high-performance liquid chromatography. J. Chromatogr. 328, 279-287 (1985). HPTLC of bis-quaternary aminosteroids (pipecuronium bromide and related steroids) on silica with methanol - acetonitrile - conc. NH3 514:386:100 containing 0.005 mole/l ammonium chloride and 0.08 mole/l ammonium carbonate. Detection by immersion of the plate in Dragendorff reagent. Densitometry by absorbance at 525 nm.

      Classification: 17c, 32a
Page