CAMAG® TLC Visualizer 2

    Professional imaging and documentation system for TLC/HPTLC chromatograms and other planar objects with a state-of-the-art digital CCD camera, connected by USB 3.0.

CAMAG® TLC Visualizer 2

The visual presentation of the complete chromatogram showing all samples and standards side by side is one of the most convincing arguments for (High-Performance) Thin-Layer Chromatography. No other chromatographic technique can directly express the result as a color image and make it available for visual evaluation.

To reproducibly acquire and preserve best quality images of TLC/HPTLC chromatograms under different illuminations this high-end imaging and documentation system is available. With its digital CCD camera a maximum resolution of 82 μm on the plate is obtained.

For electronic image acquisition the camera – like the human eye – captures polychromatic visible light. Under white light illumination it is the light reflected from the layer background. Under long-wavelength UV light (366 nm) it is the light emitted by fluorescent substances. When short-wavelength UV light (254 nm) is used, substances absorbing UV 254 appear as dark zones, provided the layer contains a fluorescence indicator (fluorescence quenching).

Key Features

  • CCD camera
  • Illumination under UV 254 nm, UV 366 nm, and white light
  • Side by side comparison of tracks with Comparison Viewer
  • Image-based evaluation
  • Any plate format up to 20 x 20 cm
  • Software-controlled with visionCATS

TLC Visualizer 2 operated under visionCATS

visionCATS organizes the workflow of TLC/HPTLC, controls the involved CAMAG instruments, and manages data. Professional image acquisition and documentation of TLC/HPTLC chromatograms ensuring highest reproducibility is the major purpose of the TLC Visualizer 2.

For the evaluation of acquired images sophisticated enhancement tools and also functions for annotation and determination of position (RF) are required. This is where visionCATS comes into play and virtually unleashes the power of TLC/HPTLC. visionCATS features a powerful database at its heart, enabling an all new sample-based approach. The state-of-the-art software supports low-noise, high-dynamic-range imaging (HDRI) and includes a comprehensive set of image enhancement tools. With the “Comparison Viewer”, tracks originating from the same or different plates and/or different illumination modes can be compared on the same screen side by side which allows the creation of „virtual plates“. Detailed on-screen instructions effectively guide the user through the image acquisition process.

Data View

The Data View allows for visual evaluation of a plate in different illumination modes and offers broad range of helpful tools, e.g. a RF tool displays the RF value of zones on the digital image or a rectangular zoom function.

Comparison Viewer

Comparison Viewer: Selected tracks of images taken from different plates under UV 254 nm, white light and UV 366 nm can be displayed side by side.

Image Enhancement

The image enhancement tools featured in visionCATS exploit the full potential of the TLC Visualizer 2. Images are automatically captured based on an optimized control of the illumination and parameters specified in the TLC/HPTLC method. Sophisticated algorithms guarantee the highest image quality for identification of even the weakest zones.

HDRI is a technique used to reproduce a greater dynamic range of luminance levels. Multiple standard-dynamic range images are taken at different exposures to capture details in shadows or highlights, and are merged into a single HDR image. For HDR images under UV 366 nm a set of dedicated enhancement tools is available. „Exposure Normalization” allows the retreatment of the image by normalizing the exposure: the gain is adjusted to an equivalent of 85% detector response based on a selected area (reference track by default). The tool is used to allow visual comparison of images from different plates with virtually the same exposure settings. The „Clarify“ tool virtually changes the illumination setting after capturing and makes very faint zones visible on an unchanged background.

Localization of even the smallest fractions on the plate with the „Spot Amp” tool which allows increasing or decreasing the contrast of the image. With „Clean Plate Correction“ an image taken of a neat plate prior to sample application can be subtracted from the image of the developed plate. Thus irregularities of the TLC/HPTLC plate, particularly the structure of the fluorescence indicator, or small variations in layer thickness seen in transmission mode, are efficiently eliminated. The “Clean Plate Correction” is significantly improved due to the increased resolution of the CCD camera in the TLC Visualizer 2.

Image Enhancement

Exposure Normalization for visualization of weak zones (right) and original image (left)

Clean Plate Correction

Clean Plate Correction: the corrected image (right) is of superb quality. Due to reduced noise, weaker zones become detectable.

Comparison Viewer

The Comparison Viewer allows easy side by side comparison of tracks from different TLC/HPTLC plates and different detection modes on the same screen:

  • Simultaneous display of reference and sample tracks from different plates
  • Creation of virtual plates from tracks originating from the same and/or different plates and/or detection modes
  • Automatic transfer of all track information from an analysis to the Comparison Viewer, e.g. plate state (clean, developed, derivatized), wavelengths, RF value, and display settings
  • Comparison Viewer report including sample details, track information and reference details
  • Comparison Viewer files can be exported and transferred to a different visionCATS installation
  • Traceability of all generated data to the original analysis

Comparison Viewer

Create virtual plates from tracks originating from different plates and detection modes

Image-based evaluation

visionCATS software enables an image-based evaluation of chromatograms obtained with the TLC Visualizer 2.

  • Conversion of images TLC/HPTLC chromatograms into analogue curves based on absorption or fluorescence of separated zones
  • Integration of chromatograms resulting in quantitative peak data (area and/or height)

Profile Comparison

  • Display of individual chromatograms
  • Position of peaks (RF value / migration distance) can be determined
  • Comparison of chromatograms from the same or different plate / image

Evaluation

  • Intuitive data management
  • Several calibration modes (e.g. single level, multi-level, related substances)
  • Re-evaluation of data at any time
3D image profile

3D image profile

Substance assignment

Substance assignment

Substance assignment

Substance assignment

Downloads

Brochure
pdf
Instruction Manual
pdf
Declaration of Conformity
pdf

Technical Specifications

Object size supported

With 12 mm lens: up to 20 x 20 cm

With 16 mm lens: up to 20 x 10 cm

Light sources

2 x UV tube short wavelength (254 nm) - direct light

2 x UV tube long wavelength (366 nm) - direct light

2 x white light tube - direct light (remission)

2 x white light tube - transmitted light (transmission)

Camera type

Digital CCD camera, sensor „SONY Super HAD CCD“, HDR

Camera exposure time

2.3 ms to 10 s, up to 60 s for HDRI, min. step size 1 μs

Connections

USB 3.0 and RS-232 serial port

Power connection

100–240 V, 50/60 Hz, 50 W

Software for instrument control

visionCATS (2.3 or higher) on MS Windows 7 and Windows 10

Dimensions (W x D x H)

480 x 537 x 596 mm

Weight

17 kg

Ordering Information

022.9810

CAMAG® TLC Visualizer 2 documentation system with 12 mm lens

without visionCATS software. Suited for object formats up to about 21 x 28 cm (20 x 20 cm TLC plates). visionCATS software mandatory and is not included

022.9811

CAMAG® TLC Visualizer 2 documentation system with 16 mm lens

without visionCATS software. Suited for object formats up to about 16 x 21 cm (20 x 10 cm and 10 x 10 cm TLC/HPTLC plates). visionCATS software mandatory and is not included

028.0000

CAMAG® HPTLC Software visionCATS Basic Version

including access and control of all instruments - 1 server, 1 client Instrument Diagnostics (xQ), analytical reports - access to method library. Needs to be bought separately and is not included in any Ultimate Package

028.1000

CAMAG® HPTLC Software visionCATS: visionCATS Ultimate

combining: Visualizer Ultimate Package (028.2000), Scanner Ultimate Package (028.3000); CAMAG HPTLC Software visionCATS Basic Version (028.0000) needs to be purchased separately

028.2000

CAMAG® HPTLC Software visionCATS: Visualizer Ultimate Package

combining all CAMAG Visualizer Packages, including: Visualizer Qualitative Package (028.2010), Visualizer Enhanced Evaluation Package (028.2020); CAMAG HPTLC Software visionCATS Basic Version (028.0000) needs to be purchased separately

028.2010

CAMAG® HPTLC Software visionCATS: Visualizer Qualitative Package

028.2020

CAMAG® HPTLC Software visionCATS: Visualizer Enhanced Evaluation Package

Background-light